Cataracts are the world’s leading cause of blindness. The latest estimation of WHO shows that almost 20 million people currently suffer from blindness caused by Age related Cataract.
The Thind Eye Hospital offers the patients a broad spectrum of products for Cataract evaluation including diagnostic instruments, device for measuring the parameters required fir IOL computation & lasers for after Cataract therapy. |
| |
Phacoemulsification (No stitch, No injection, No bandage) - is a micro-incision technique of cataract surgery wherein an ultrasound probe breaks the cataract into tiny pieces and sucks them out. If a foldable implant is inserted the incision size is smaller (2.8 - 3.0 mm) as compared to an approximately 5 mm incision to accommodate a non-foldable lens. Both incisions are self-sealing and need no stitches.
|
Sovereign Phacoemulsification System
From plus-4 cataracts to soft lens removal, WhiteStar Cold Phaco Technology allows surgeons to safely remove all lens types through the smallest possible incisions with single-mode, single-instrument convenience — using little or no ultrasound. It’s the bridge between today’s most advanced cataract technologies and tomorrow’s opportunities with microincision lens removal.
WhiteStar Cold Phaco Technology is a patented software application proven to change the characteristics of phacoemulsification using little to no ultrasound. This is done by changing the thermal properties and improving control of the lens without reducing the cutting power or changing technique or efficiency. |
 |
| |
|
Oertli Phacoemulsification System
Micro-Pulsed Ultrasound Phaco (CMP technology manufactured by Oertli instruments), is the key to sleeveless bimanual 1.5 mm phaco, elimination of wound burns, reduction of ultrasound time, improved capacity to capture nuclear fragments, elimination of induced astigmatism and clear corneas immediately post-op. Surgeons can select the preferred pulse frequency and cooling factor, and a specially designed software ensures that values chosen will guarantee cool phaco. |
 |
Millennium storz (B & L)
Bausch & Lomb Surgical’s new Storz Millennium Microsurgical System is a modular system that addresses the needs of several eye surgical specialties, including cataract removal, retinal reattachment, glaucoma, and cornea repair. The Millennium’s advanced surgical features include new pump technology for either a flow or vacuum-based aspiration system from the eyes, high-performance ultrasound delivery for cataract removal, a dual light source, and electric scissors. |
| |
Allergan Diplomax |
| |
 |
| |
|
| |
 |
The slit lamp is a microscope with a light attached that allows the doctor to examine your eye under high magnification. This instrument is primarily used to view the anterior structures of the eye such as the cornea, iris, and lens. However, with special lenses, it is possible to examine the vitreous and the back of the eye as well. |
| |
|
|
|
IOL Master
The IOLMaster is used for biometric measurement and preoperative computation of intraocular lens (IOL) power. Non-contact Optical Coherence Biometry revolutionizes measurement of the ocular axis and sets new standards for speed and accuracy. |
| |
 |
| |
- Precise axial length measurements along the visual axis greatly increase technician and surgeon confidence.
- Non-contact optical biometry – easy on the patient: no local anesthesia and no risk of abrasion or spread of infection from patient to patient.
- Multiple operators, same measurement results – as clinical studies show, the IOLMaster provides user-independent measurement results.
- Improved refractive results through personalized IOL constants computed by the integrated optimization algorithm on the basis of your postoperative data.
- Performance, simplicity, efficiency – the IOLMaster provides all biometric parameters required for IOL power calculation in a natural, user-friendly sequence in a single location.
A-Scan Sonomed -The digital A-scan system provides a large liquid crystal display. The combination of a high frequency, low noise probe and fast precise algorithm enables scan capture immediately upon application of the probe along the visual axis. |
| |
|
Features
- Live A-Scan Display
- Storage of 5 Different User Profiles
- Measurement Review Capability
- 4 Different IOL Formulas
- Clinical Accuracy +/- 0.1 mm
|
 |
|
| |
|
| |
| |
|
Zeiss Visu 200
It is surgical microscope that can only be described as absolute state-of-the-art for ophthalmic surgery. Its wide range of uses meet the demands placed on it by surgeons and it offers new functions to improve depth of field, resolution and contrast. |
 |
|
| |
|
| |
The NIDEK YC-1400 is the new disruption laser from NIDEK designed in particular for applications in posterior capsulotomy (post-cataract therapy) and iridotomy. However, the YAG laser is also used for trabeculotomy, anterior capsulotomy and for IOL polishing. |
 |
|
| |
|
| |
 |
Hydrophilic Acrylic Lenses for Cataract Surgery |
 |
Ophthalmic Viscosurgical Devices |
 |
Hydrophobic Lenses for Cataract Surgery |
 |
ICL/TICL for Refractive Surgery |
 |
Disposable Surgical Instrumentation |
 |
Irrigation Solutions |
 |
Personalized Surgical Pack |
 |
Non-absorbable Glaucoma Drain |
 |
Capsular Tension Ring |
|
| |
|